Menu

Verila Syntech EP 2

Synthetic - Long Life - High Performance - Extreme Pressure [EP] Lithium Complex Grease - for Extremely Low Temperatures and High Speeds

Verila Syntech EP 2 is a premium quality, synthetic base lubricating grease containing polyalphaolefin (PAO) synthetic base oils, and high performance dilithium sebacate base lithium complex soap. Synthetic, PAO base oil and its wax-free structure makes this product suitable for applications within a wide temperature range, especially at extremely low temperatures. The product is formulated with the latest additive technology which deliver to grease the right balance of performance characteristics. Excellent oxidation stability, coupled with rust and corrosion prevention, superior AW/EP performance as well as excellent water resistance extends bearing life and that means less downtime.

  • Excellent at extremely low temperatures, easy start even at the temperatures down to -450C
  • Recommended for High Speeds, n dm values of 1.000.000
  • Superior Oxidation Stability and Ageing Resistance.
  • High Load Carrying Capacity and Excellent wear control
  • Very Good Mechanical Stability
  • Excellent Corrosion Protection and Good Water Resistance

Superb quality, synthetic, long life, extreme pressure grease developed for the automotive and industrial applications where infrequent re-greasing is mandatory; bearings operate at high speeds and are exposed to extremely low temperatures. Typical application are small electric motors, textile and machine spindle bearings in tools; precision Instruments.

Grease Classifications
ISO 6743-9 L-XEDHB 2 DIN 51502 KPHC2N-40
Test Parameter Test Method Value
Appearance Visual Smooth and Homogenous
Color Visual White to Light Yellow
Thickener   Lithium Complex
Base Oil Viscosity at 40 Celsius, mm2/s EN ISO 3104 32
NLGI Grade ASTM D217 2
Operating Temperature Range   -45 to 150 Celsius
Cone Penetration, Worked, 0.1 mm ISO 2137 265 – 295
Dropping Point ISO 6299 > 220 Celsius
Corrosive Effects on Copper ASTM D4048 max 1
Dynamic Rust Test, EMCOR ISO 11007 0-0
Water Washout Test at 79 Celsius, wt.% loss ISO 11009 < 6
Four-Ball EP Test, Weld Point, N ASTM D2596 min 2500
Flow Pressure, -40 Celsius, hPa DIN 51805 1250 @ -40 Celsius

While the information and figures given here are typical of current production and compliant with VERILA specification, minor variations may occur